Objective To explore the intra- and inter-rater reliability of shear wave elastography (SWE) for the patellar tendon and quadriceps femoris stiffness.Methods From October to November, 2017, the stiffness of the patellar tendon and quadriceps femoris of 20 healthy men was measured by SWE, and measured again five days later. The results were evaluated with interclass correlation coefficient (ICC).Results For patellar tendon, ICC=0.79 in intra-rater and inter-rater; for rectus femoris, ICC=0.71 in intra-rater and 0.73 in inter-rater; for vastus lateralis muscle, ICC=0.84 in intra-rater and 0.74 in inter-rater; for vastus medialis,ICC=0.95 in intra-rater and 0.94 in inter-rater.Conclusion It is a reliable and repeatable method to measure the stiffness of patellar tendon and quadriceps femoris by SWE.
QIN Kun
,
FENG Ya-nan
,
LI Ya-peng
,
SHEN Su-hong
,
LIU Chun-long
,
ZHANG Zhi-jie
. Intra- and Inter-rater Reliability of Shear Wave Elastic Imaging Technique for Elastic Modulus Measurements of Muscle and Tendon[J]. Chinese Journal of Rehabilitation Theory and Practice, 2018
, 24(10)
: 1201
-1205
.
DOI: 10.3969/j.issn.1006-9771.2018.10.015
[1] Shiina T, Nightingale KR, Palmeri ML, et al.WFUMB guidelines and recommendations for clinical use of ultrasound elastography, part 1: basic principles and terminology[J]. Ultrasound Med Biol, 2015, 41: 1126-1147.
[2] Szczepanek-Parulska E, Wolinski K, Stangierski A, et al.Comparison of diagnostic value of conventional ultrasonography and shear wave elastography in the prediction of thyroid lesions malignancy[J]. PLoS One, 2013, 8: 81532.
[3] Bensamoun SF, Ringleb SI, Chen Q, et al.Thigh muscle stiffness assessed with magnetic resonance elastography in hyperthyroid patients before and after medical treatment[J]. J Magn Reson Imaging, 2007, 26: 708-713.
[4] Chen XM, Cui LG, He P, et al.Shear wave elastographic characterization of normal and torn Achilles tendons: a pilot study[J]. J Ultrasound Med, 2013, 32: 449-455.
[5] Zhang ZJ, Ng GYF, Lee WC, et al.Increase in passive muscle tension of the quadriceps muscle heads in jumping athletes with patellar tendinopathy[J]. Scand J Med Sci Sports, 2017, 27(10): 1099-1104.
[6] Yoshitake Y, Takai Y, Kanehisa H, et al.Muscle shear modulus measured with ultrasound shear-wave elastography across a wide range of contraction intensity[J]. Muscle Nerve, 2014, 50: 103-113.
[7] Hug F, Bouillard K, Nordez A, et al.Characterization of passive elastic properties of the human medial gastrocnemius muscle belly using supersonic shear imaging[J]. J Biomech 2012, 45: 978-984.
[8] Lacourpaille L, Hug F, Bouillard K, et al.Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus[J]. Physiol Meas, 2012, 33: 19-28.
[9] Hirayama K, Akagi R, Takahashi H.Reliability of ultrasound elastography for the quantification of transversus abdominis elasticity[J]. Acta Radiol Open, 2015, 4: 1-4.
[10] Cortez CD, Hermitte L, Ramain A, et al.Ultrasound shear wave velocity in skeletal muscle: a reproducibility study[J]. Diagn Interv Imaging, 2015, 97: 71-79.
[11] Peltz C, Haladik J, Divine G, et al.Shear wave elastography: repeatability for measurement of tendon stiffness[J]. Skeletal Radiol, 2013, 42: 1151-1156.
[12] Bercoff J, Tanter M, Fink M.Supersonic shear imaging: a new technique for soft tissue elasticity mapping[J]. IEEE Trans Ultrason Ferroelectr Freq Control, 2004, 51(4): 396-409.
[13] Warren DY, Panossian V, Hatch JD, et al.Combined effects of estrogen and progesterone on the anterior cruciate ligament[J]. Clin Orthop Relat Res, 2001, 383: 268-281.
[14] Martinson H, Stokes M.Measurement of anterior tibial muscle size using real-time ultrasound imaging[J]. Eur J Appl Physiol Occup Physiol, 1991, 63: 250-254.
[15] Tas S, Onur MR, Yilmaz S, et al.Shear wave elastography is a reliable and repeatable method for measuring the elastic modulus of the rectus femoris muscle and patellar tendon[J]. J Ultrasound Med, 2017, 36(3): 565-570.