《Chinese Journal of Rehabilitation Theory and Practice》 ›› 2021, Vol. 27 ›› Issue (6): 698-705.doi: 10.3969/j.issn.1006-9771.2021.06.011

Previous Articles     Next Articles

Effect of Microelectronic Electromyography Bridge on Motor Function of Extensor Carpi Radialis Longus in Patients with Cervical Spinal Cord Injury

Chong WANG1,2,4,Liang-jie DU1,3,4(),Zhi-gong WANG5,Jian-jun LI1,3,4,Jun LI1,3,4,Hong-wei LIU1,3,4,Fang CONG1,2,4,Xin LIN1,2,4   

  1. 1.Capital Medical University School of Rehabilitation Medicine, Beijing 100068, China
    2.Department of Physiotherapy, Beijing Bo'ai Hospital, China Rehabilitation Research Center, Beijing 100068, China
    3.Department of Spinal and Neural Function Reconstruction, Beijing Bo'ai Hospital, China Rehabilitation Research Center, Beijing 100068, China
    4.Institute of Nerve Injury and Repair, Beijing Key Laboratory of Nerve Injury and Rehabilitation, Beijing Institute of Brain Diseases, Chinese Institute of Rehabilitation Sciences, Beijing 100068, China
    5.Institute of Radiofrequency and Optoelectronic Integrated Circuits, Southeast University, Nanjing, Jiangsu 210000, China
  • Received:2021-01-26 Revised:2021-04-14 Published:2021-06-25 Online:2021-06-21
  • Contact: Liang-jie DU E-mail:duliangjie@mail.ccmu.edu.cn
  • Supported by:
    Fundamental Research Funds for Central Public Welfare Research Institutes(2015-4-48-1)

Abstract: Objective

To observe the effect of microelectronic EMG bridge (EMGB) training on the motor function of extensor carpi radialis longus in patients with complete cervical 5 spinal cord injury.

Methods

From March, 2016 to March, 2017, 20 patients with complete cervical 5 spinal cord injury were randomly divided into control group (n = 10) and experimental group (n = 10). The control group received routine wrist extensor muscle training, and the experimental group received EMGB training in addition, for 180 days. The motor function of the affected limb was evaluated by sEMG of extensor carpi radialis longus, Manual Muscle Test (MMT), Wolf Motor Function Test (WMFT) and Spinal Cord Lesion Independence Measure (SCIM).

Results

After treatment, the peak value and average value of sEMG of extensor carpi longus of both sides increased in both groups (t > 2.510, P < 0.05), the peak value and average value of the left side were higher (t > 2.759, P < 0.05), and the peak value of the right side was higher (t = 2.691, P < 0.05) in the experiment group than in the control group, however, there was no significant difference in average value of the right side between two groups (t = 2.063, P = 0.054). The scores of MMT increased in both groups (t > 2.569, P < 0.05), and were higher in the experimental group than in the control group (t > 2.278, P < 0.05). The scores of WMFT and SCIM increased in both groups (t > 3.839, P < 0.05), however, there was no significant difference between two groups (t < 1.498, P > 0.05).

Conclusion

EMGB training could improve the motor function of extensor carpi radialis longus in patients with complete cervical 5 spinal cord injury.

Key words: spinal cord injury, microelectronic electromyography bridge, extensor carpi radialis longus, rehabilitation