Abstract

Objective To explore the best methods of catheterization in patients with neurogenic bladder using clean intermittent self-catheterization. Methods From December, 2014 to December, 2015, sixty patients with neurogenic bladder were equally divided into observation group who were taught the non-contact clean intermittent self-catheterization, and control group who were taught routine clean intermittent self-catheterization. Their materials, times to learn, and the incidence of catheter contamination and urinary tract infection were compared. Results The observation group mastered the catheterization in fewer times of learning than the control group (Z=- 4.400, P< 0.001). The incidence of catheter contamination (χ2=5.880, P=0.015) and urinary tract infection (χ2=4.043, P=0.044) were less in the observation group than in the control group. Conclusion Non-contact clean intermittent catheterization is beneficial to manage neurogenic bladder.

Cite this article

DENG Shui-juan1a , ZHOU Jun-gui1a , LIU Yu1a , HE Ren-hong1a , QIAN Da-di1b . Application of Non-contact Technology in Clean Intermittent Self-catheterization[J]. Chinese Journal of Rehabilitation Theory and Practice, 2016 , 22(9) : 1101 -1103 . DOI: 10.3969/j.issn.1006-9771.2016.09.026