Progress of Wearable Technology in Rehabilitation Medicine (review)

  • ZHANG Wen-hao ,
  • LI Jian-jun ,
  • GAO Feng ,
  • YANG De-gang ,
  • GUO Yun ,
  • LIU Chang-bin ,
  • YANG Ming-liang ,
  • DU Liang-jie ,
  • CUI Yao ,
  • LI Da-peng ,
  • ZHANG Xin ,
  • CAI Chang ,
  • ZHANG Jie
Expand
  • 1. Capital Medical University School of Rehabilitation Medicine, Beijing 100068, China;
    2. a. Department of Spinal and Neural Function Reconstruction; b. Hydrotherapy Room, China Rehabilitation Research Center, Beijing Bo'ai Hospital, Beijing 100068, China;
    3. Center of Neural Injury and Repair, Beijing Institute for Brain Disorders, Beijing 100068, China;
    4. Beijing Key Laboratory of Neural Injury and Rehabilitation, Beijing 100068, China

Received date: 2017-01-20

  Online published: 2017-08-07

Abstract

With the development of science and technology, and the emergence of artificial intelligence, wearable technology is becoming a hot topic in the field of rehabilitation medicine. Wearable technology is characterized by miniaturization, intelligency and convenience, and has been widely researched and applied in many fields, such as neurological rehabilitation, orthopaedic rehabilitation, spinal cord injury rehabilitation and rehabilitation for senile degenerative diseases. The further research may focus on the reliability of signals under dynamic monitoring, the comfortable feeling during long-term use of wearable devices, the data security based on personal privacy, and so on.

Cite this article

ZHANG Wen-hao , LI Jian-jun , GAO Feng , YANG De-gang , GUO Yun , LIU Chang-bin , YANG Ming-liang , DU Liang-jie , CUI Yao , LI Da-peng , ZHANG Xin , CAI Chang , ZHANG Jie . Progress of Wearable Technology in Rehabilitation Medicine (review)[J]. Chinese Journal of Rehabilitation Theory and Practice, 2017 , 23(7) : 792 -795 . DOI: 10.3969/j.issn.1006-9771.2017.07.011

References

[1] Qureshi AZ. FCPS training in the specialty of Physical Medicine and Rehabilitation for physicians in Pakistan: The option less known [J]. J Pak Med Assoc, 2016, 66(1): 93-96.
[2] 刘冬梅. 浅谈康复医学在综合型医院的发展状况[J]. 内蒙古中医药, 2013, 32(32): 109-110.
[3] 叶雯珺,李智军. 可穿戴便携式康复外骨骼机器人的开发[J]. 集成技术, 2013, 2(4): 27-31.
[4] 朱婧. 国内外可穿戴行业发展动态与趋势[J]. 广东科技, 2015, 24(14): 9-12.
[5] 周达岸,李建军. 下肢外骨骼机器人的现状与展望[J]. 中国康复理论与实践, 2013, 19(12): 1132-1134.
[6] 陈亚芹,黄光明. 穿戴式肩周炎物理治疗监测系统设计[J]. 电子测量技术, 2016, 39(3): 166-170.
[7] Appelboom G, Camacho E, Abraham ME, et al. Smart wearable body sensors for patient self-assessment and monitoring [J]. Arch Public Health, 2014, 72(1): 28. doi:10.1186/2049-3258-72-28.
[8] 颜延,邹浩,周林,等. 可穿戴技术的发展[J]. 中国生物医学工程学报, 2015, 34(6): 644-653.
[9] 黄海诚,汪丰. 可穿戴技术在医疗中的研究与应用[J]. 中国医疗设备, 2015, 30(1): 1-5.
[10] Pantelopoulos A, Bourbakis N. A survey on wearable biosensor systems for health monitoring [J]. Conf Proc IEEE Eng Med Biol Soc, 2008, 2008: 4887-4890.
[11] 单新颖,张腾宇,张晓玉. 可穿戴技术在康复辅具领域的应用研究[J]. 中国康复医学杂志, 2016, 31(10): 1149-1151.
[12] Yingling LR, Mitchell V, Ayers CR, et al. Adherence with physical activity monitoring wearable devices in acommunity-based population: observations from the Washington, D.C., Cardiovascular Health and Needs Assessment [J]. Transl Behav Med, 2017-01-17. doi:10.1007/s13142-016-0454-0. [Epub ahead of print]
[13] Ajami S, Teimouri F. Features and application of wearable biosensors in medical care [J]. J Res Med Sci, 2015, 20(12): 1208-1215.
[14] Patel S, Park H, Bonato P, et al. A review of wearable sensors and systems with application in rehabilitation [J]. J Neuroeng Rehabil, 2012, 9: 21. doi:10.1186/1743-0003-9-21.
[15] Shull PB, Jirattigalachote W, Hunt MA, et al. Quantified self and human movement: a review on the clinical impact of wearable sensing and feedback for gait analysis and intervention [J]. Gait Posture, 2014, 40(1): 11-19.
[16] 蔡新源. 可穿戴式上肢康复机器人系统设计与实现[D]. 西安:长安大学, 2015.
[17] Jovanov E, Milenkovic A, Otto C, et al. A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation [J]. J Neuroeng Rehabil, 2005, 2(1): 6. doi:10.1186/1743-0003-2-6
[18] Wang W, Jiang B, Sun H, et al. Prevalence, incidence and mortality of stroke in China: Results from a nationwide population-based survey of 480,687 adults [J]. Circulation, 2017, 135(8): 759-771.
[19] Goonewardene SS, Baloch K, Porter K, et al. Road traffic collisions-case fatality rate, crash injury rate, and number of motor vehicles: time trends between a developed and developing country [J]. Am Surg, 2010, 76(9): 977-981.
[20] Tao W, Liu T, Zheng R, et al. Gait analysis using wearable sensors [J]. Sensors (Basel), 2012, 12(2): 2255-2283.
[21] Lopez-Meyer P, Fulk GD, Sazonov ES. Automatic detection of temporal gait parameters in poststroke individuals [J]. IEEE Trans Inf Technol Biomed, 2011,15(4): 594-601.
[22] Stokic DS, Horn TS, Ramshur JM, et al. Agreement between temporospatial gait parameters of an electronic walkway and a motion capture system in healthy and chronic stroke populations [J]. Am J Phys Med Rehabil, 2009, 88(6): 437-444.
[23] Rand D, Eng JJ, Tang PF, et al. How active are people with stroke? use of accelerometers to assess physical activity [J]. Stroke, 2009, 40(1): 163-168.
[24] Cook RE, Schneider I, Hazlewood ME, et al. Gait analysis alters decision-making in cerebral palsy [J]. J Pediatr Orthop, 2003, 23(3): 292-295.
[25] Filho MC, Yoshida R, Carvalho WS, et al. Are the recommendations from three-dimensional gait analysis associated with better postoperative outcomes in patients with cerebral palsy? [J]. Gait Posture, 2008, 28(2): 316-322.
[26] Lockman J, Fisher RS, Olson DM. Detection of seizure-like movements using a wrist accelerometer [J]. Epilepsy Behav, 2011, 20(4): 638-641.
[27] Frankewycz B, Krutsch W, Weber J, et al. Rehabilitation of Achilles tendon ruptures: is early functional rehabilitation daily routine? [J]. Arch Orthop Trauma Surg, 2017, 137(3): 333-340.
[28] Turcot K, Aissaoui R, Boivin K, et al. New accelerometric method to discriminate between asymptomatic subjects and patients with medial knee osteoarthritis during 3-D gait [J]. IEEE Trans Biomed Eng, 2008, 55(4): 1415-1422.
[29] McAlindon TE, Bannuru RR, Sullivan MC, et al. OARSI guidelines for the non-surgical management of knee osteoarthritis [J]. Osteoarthritis Cartilage, 2014, 22(3): 363-388.
[30] Fransen M, McConnell S, Harmer AR, et al. Exercise for osteoarthritis of the knee: a Cochrane systematic review [J]. Br J Sports Med, 2015, 49(24): 1554-1557.
[31] van Gool CH, Penninx BW, Kempen GI, et al. Effects of exercise adherence on physical function among overweight older adults with knee osteoarthritis [J]. Arthritis Rheum, 2005, 53(1): 24-32.
[32] Papi E, Belsi A, McGregor AH. A knee monitoring device and the preferences of patients living with osteoarthritis: a qualitative study [J]. BMJ Open, 2015, 5(9): e7980.
[33] Cempini M, Marzegan A, Rabuffetti M, et al. Analysis of relative displacement between the HX wearable robotic exoskeleton and the user's hand [J]. J Neuroeng Rehabil, 2014, 11: 147. doi:10.1186/1743-0003-11-147.
[34] Wang H, Liu X, Zhao Y, et al. Incidence and pattern of traumatic spinal fractures and associated spinal cord injury resulting from motor vehicle collisions in China over 11 years: An observational study [J]. Medicine (Baltimore), 2016, 95(43): e5220.
[35] Yang R, Guo L, Huang L, et al. Epidemiological characteristics of traumatic spinal cord injury in Guangdong, China [J]. Spine (Phila Pa 1976), 2017, 42(9):E555-E561. doi:10.1097/BRS.0000000000001896.
[36] Jain NB, Ayers GD, Peterson EN, et al. Traumatic spinal cord injury in the United States, 1993-2012 [J]. JAMA, 2015, 313(22): 2236-2243.
[37] Spinal cord injury facts and figures at a glance [J]. J Spinal Cord Med, 2012, 35(6): 480-481.
[38] Aldahmash A, Zaher W, Al-Nbaheen M, et al. Human stromal (mesenchymal) stem cells: basic biology and current clinical use for tissue regeneration [J]. Ann Saudi Med, 2012, 32(1): 68-77.
[39] Strickland ER, Hook MA, Balaraman S, et al. MicroRNA dysregulation following spinal cord contusion: implications for neural plasticity and repair [J]. Neuroscience, 2011, 186: 146-60. doi:10.1016/j.neuroscience.2011.03.063.
[40] Routhier F, Vincent C, Desrosiers J, et al. Mobility of wheelchair users: a proposed performance assessment framework [J]. Disabil Rehabil, 2003, 25(1): 19-34.
[41] Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of human walking during load carriage [J]. J Neuroeng Rehabil, 2014, 11: 80. doi:10.1186/1743-0003-11-80.
[42] Sale P, Russo EF, Russo M, et al. Effects on mobility training and de-adaptations in subjects with spinal cord injury due to a wearable robot: a preliminary report [J]. BMC Neurol, 2016, 16: 12. doi:10.1186/s12883-016-0536-0.
[43] Esquenazi A, Talaty M, Packel A, et al. The ReWalk powered exoskeleton to restore ambulatory function to individuals with thoracic-level motor-complete spinal cord injury [J]. Am J Phys Med Rehabil, 2012, 91(11): 911-921.
[44] Zeilig G, Weingarden H, Zwecker M, et al. Safety and tolerance of the ReWalk exoskeleton suit for ambulation by people with complete spinal cord injury: a pilot study [J]. J Spinal Cord Med, 2012, 35(2): 96-101.
[45] Neloska L, Damevska K, Nikolchev A, et al. The association between malnutrition and pressure ulcers in elderly in long-term care facility [J]. Open Access Maced J Med Sci, 2016, 4(3): 423-427.
[46] Graham WV, Bonito-Oliva A, Sakmar TP. Update on Alzheimer's Disease Therapy and Prevention Strategies [J]. Annu Rev Med, 2017, 68: 413-430. doi:10.1146/annurev-med-042915-103753.
[47] 徐迎阳. 可穿戴设备现状分析及应对策略[J]. 现代电信科技, 2014(4): 73-76.
[48] Valdes P, Schneider BL. Gene therapy: a promising approach for neuroprotection in Parkinson's disease? [J]. Front Neuroanat, 2016, 10: 123. doi:10.3389/fnana.2016.00123
[49] Bachlin M, Plotnik M, Roggen D, et al. Wearable assistant for Parkinson's disease patients with the freezing of gait symptom [J]. IEEE Trans Inf Technol Biomed, 2010, 14(2): 436-446.
[50] Moore ST, MacDougall HG, Ondo WG. Ambulatory monitoring of freezing of gait in Parkinson's disease [J]. J Neurosci Methods, 2008, 167(2): 340-348.
[51] 张华. 助听器产品与服务进展[J]. 临床耳鼻咽喉头颈外科杂志, 2013, 27(16): 864-867.
[52] Bergmann JH, McGregor AH. Body-worn sensor design: what do patients and clinicians want? [J]. Ann Biomed Eng, 2011, 39(9): 2299-2312.
[53] Bergmann JH, Chandaria V, McGregor A. Wearable and implantable sensors: the patient's perspective [J]. Sensors (Basel), 2012, 12(12): 16695-16709.
[54] Pigini L, Bovi G, Panzarino C, et al. Pilot test of a new personal health system integrating environmental and wearable sensors for telemonitoring and care of elderly people at home (SMARTA Project) [J]. Gerontology, 2017, 63(3): 281-286.
Outlines

/