《Chinese Journal of Rehabilitation Theory and Practice》 ›› 2006, Vol. 12 ›› Issue (02): 140-142.

• 临床研究 • Previous Articles     Next Articles

Test-retest Reliability and Inter-rater Reliability of ASIA2000 Scale

WANG Fang-yong, LI Jian-jun, HONG Yi   

  1. The Department of Spinal Column and Spinal Cord Surgery, Beijing Charity Hospital, Beijing 100068, China
  • Received:2005-08-01 Published:2006-02-25 Online:2006-02-25

Abstract: ObjectiveTo investigate the test-retest reliability and inter-rater reliability of ASIA2000 scale.MethodsTwenty-five hospitalized spinal cord injury volunteers were chosen according to the selective criteria. The items were retested by the same examiner one week later to determine the scale's test-retest reliability. Another doctor did the same work 24 h later to determine the scale's inter-rater reliability.ResultsThe Pearson correlation coefficients of the pin prick score, light touch score and motor score of the test-retest reliability were all above 0.90 (P<0.05), and the Kappa values of the ASIS impairment scale (AIS) and completeness of the injury were 0.787 and 0.756 (P<0.05). The Pearson correlation coefficients of the pin prick score, light touch score and motor score of the inter-rater reliability were all above 0.85 (P<0.05), and the Kappa values of the AIS and completeness of the injury were 0.802 and 0.764 (P<0.05).ConclusionThe ASIA2000 scale has good test-retest reliability and inter-rater reliability.

Key words: spinal cord injury, ASIA2000 scale, reliability